I�C was designed to communicate over short distances between printed circuit boards and is really a simple, 8-bit serial data bus. For the time being, it isn’t only PCB-mountable pressure sensors that use the I�C signal for data transfer, but additionally pressure sensors remote from customer electronics.
Remote sensors usually have the benefit of being less sensitive to contaminated or aggressive media and being able to measure directly at the procedure. Regarding sensors mounted directly on the circuit board, the sensor element is, oftentimes, exposed right to the medium. With remote sensors, steel or ceramic generally serve because the wetted surface.
I�C circuit
The I�C bus, alongside both supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than having an analogue signal:
In the info protocol, as well as the pressure value, a temperature value and diagnostic information (for example an integrity test of the info transfer) could be transmitted with a status byte.
Several pressure sensors could be connected to a bus line as ?slaves? to the client electronics that functions as a ?master?.
On the customer side, as opposed to the utilization of pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary since the pressure value has already been present in digital form. This contributes to faster and easier signal processing.
The electronics for communication could be built with standard components easily available on the market.
Often, I�C signal pressure sensors may also be optimised to consume less energy, making them ideal for battery-powered applications. In the WIKA portfolio, for example, this applies to the MPR-1 pressure sensor module.
Boundary conditions by using I�C
Since I�C isn’t a fieldbus, long wire lengths are not recommended. The utmost wire length depends, at length, on the operating environment and the corresponding disturbing influences. I�C communication is best used in projects where the pressure sensor or the pressure sensor module is integrated into the customer product and thus protected against external influences. It will also be noted that with any digitally processed signal, the response time because of discrete-time sampling will be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will undoubtedly be happy to assist you to with any more questions on digital interfaces.
Distributed Anxious
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we’ll send you the whitepaper ?Distributed Intelligence?.
Name
Company
E-mail
Send
We?re committed to your privacy. We?ll use your details to contact you about our services and products. E mail us at socialmedia@wika.com to revoke your permission to utilize your information.