The significance of supervised monitoring modules utilized in control and monitoring of extinguishing methods

In many places from chemistry laboratories to industrial services, to be able to guarantee the protection of life and property towards a possible fireplace hazard, extinguishing methods are used in addition to detection and alarm systems. It can also be extraordinarily essential that the extinguishing methods put in may be triggered by the fireplace extinguishing management panel, to be able to eliminate a potential fireplace with early intervention.
In order to fulfill these needs, and with 35 years of sectoral data and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which allows the remote efficiency of the symptoms and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be started manually and remotely; and
to guarantee that the extinguishing course of may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these devices are produced using surface-mount technology and are geared toward making the automation of the extinguishing system and fireplace and fuel detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by always considering the needs of the installation. In circumstances that require the mixing of the extinguishing system with the clever addressable hearth detection system, it offers options by way of the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an necessary role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a potential open or quick circuit in the wiring between the contact monitoring modules and the peripheral systems can cause disruption of the triggering, with doubtlessly important consequences. For this cause, when choosing monitoring modules, it must be taken under consideration that they’ve supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable fireplace detection and alarm control panels are constantly communicating with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to watch conditions corresponding to open circuits and short circuits which will occur within the system. Many duties could be carried out in the hearth extinguishing set up, such because the control and monitoring of all valves that may interrupt the move of water, water circulate alarm switches, stress switch, and electrical or diesel fireplace pumps.
By including เกจวัดแรงดันน้ำราคา monitoring modules to two separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be used to control errors and the opposite to manage the fireplace scenario, monitoring and control of the extinguishing system via an intelligent addressable fire detection and alarm system can be performed effectively.
For more data, go to www.mavili.com.tr/en
Share